Lines changed: 64 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -0,0 +1,64 @@
1+
# Batteries
2+
3+
![LiPo Battery](../assets/img/kit/battery.jpg){ width="50%" }
4+
5+
Your robot uses lithium-ion polymer (LiPo) batteries.
6+
These are similar to those used in laptops, and are small and light for
7+
the amount of energy they contain. This is great for your robot but it
8+
is vital to treat such a high concentration of energy with respect. If
9+
you do not, there is a serious risk of fire and injury. To avoid this,
10+
you should follow the safety information on this page closely, at all
11+
times.
12+
13+
!!! warning
14+
You must not use any batteries, chargers, bags or cables not explicitly authorised by SourceBots.
15+
16+
## Warnings
17+
18+
- Never leave batteries unattended when they are in use.
19+
- Always place the batteries in the provided bag when not in use.
20+
- If a battery has any cuts, nicks, exposed copper on wires or is
21+
bulging to the point of no longer being squishy, contact us
22+
immediately.
23+
24+
!!! danger
25+
Disobeying the above warnings greatly increases the risk of damage to your battery, which can have **fatal consequences**. If you have any questions or doubts, talk to a member of staff immediately.
26+
27+
## Storing batteries
28+
29+
When your batteries are not actively in use, they should be safely
30+
stored. You must disconnect the batteries from all electrical equipment,
31+
and place them in the battery charging bag. You should then store the
32+
charging bag in a safe location.
33+
34+
## Operating batteries
35+
36+
To use your batteries, you must connect them to the power board. Do not
37+
tamper with the cable or connect the batteries to anything other than
38+
the power board (or the charger when charging).
39+
40+
During operation, the battery is protected by over-current protection
41+
and a fuse in the power board. If any equipment is short circuited, the
42+
over-current protection will activate, protecting the battery. In
43+
extreme circumstances the fuse may blow to prevent damage to the
44+
battery. This is an important safety feature: do not, under any
45+
circumstances, bypass the fuse. It is not user serviceable and if it has
46+
blown then the power board must be replaced. If you suspect the fuse has
47+
blown then please contact us straight away.
48+
49+
Mechanical damage to a battery can be dangerous, and a puncture or large
50+
force applied to a battery causes a serious risk of fire. To avoid this,
51+
your battery should be shielded from mechanical damage while you operate
52+
it. Secure your battery to your robot, so that it does not move or fall
53+
off while the robot moves. You should also build a compartment for the
54+
battery to be placed in, so that accidental collisions do not damage the
55+
battery.
56+
57+
## Flat batteries
58+
59+
When the battery has been almost completely discharged, the Power Board
60+
will automatically turn off and the LED marked “Power / Flat Battery
61+
Indicator” in the [diagram](./power-board.md) will
62+
flash red and green. You should immediately disconnect the battery. Flat
63+
batteries should be given to a faciliator in exchange for a freshly charged
64+
battery.

0 commit comments